A ground fault (earth fault) is any disappointment that permits unintended association of force circuit conductors with the earth. Such faults can cause offensive circling flows, or may empower the lodgings of gear at a hazardous voltage. Earth fault is viewed as exceptionally basic on board a ship. A few ships which work at 440 V don't have any excursion gadgets joined for a solitary earth fault. Anyway when the working voltage surpasses 3000V, it is compulsory to have an insurance framework which confines when a hardware endures an earth fault.
The earnestness of the move to be made on an Earth Fault relies upon the piece of the electrical framework it influences. Regular ships which work on 3 Phase, 440V, have earth fault markers introduced on every one of the three stages. Any earth fault on a 440V framework is viewed as a genuine difficulty and prompt activity is needed to distinguish the faulty circuit. Any earth fault on 220V or any low voltage lighting circuit can be considered as significant yet need not need prompt consideration. Notwithstanding, consideration ought to be paid at the following soonest opportunity.
Solutions of Earth Fault.
Some important solutions given by the experienced technical officers are follows, which can give you idea what should YOU do as a technical officer at ship.
- Turn off power to the circuit and perform resistance checks on every component. The fault is usually found in a shorted capacitor.
- Sectionalizing which circuit causes the fault. Isolating the faulty circuit, Test if de-energized prior to do any other tests. Lock / Tag out circuit for your own safety. Then, Do insulation tests between Phases, Phase to Neutral and or cable Screens. (most likely on a ship), Continuity tests. Visual tests, may have to crawl and check for obvious damage.
- Earth fault occurs when the live phase wire comes in direct contact or through a body of very low resistance with ground and flow of current will be in terms amps or kiloamps. Earth leakage occurs due deteriation or breakdown of insulation of wire or equipment which is not grounded properly and will be in the order of milliamps . This leakage current is used protection of equipment/ personnel by using a relay to disconnect the power.
Why Earth Fault Occurs?
- Exposure to moisture 22.5%
- Shorting by tools, rodents, etc. 18.0%
- Exposure to dust 14.5%
- Other mechanical damage 12.1%
- Exposure to chemicals 9.0%
- Normal deterioration from age 7.0%
How To Find Earth Fault on 440V circuit
How To Find Earth Fault on 220V Circuit
Model: Earth Fault alarm sounds on a 220V board
- Check the certainty of the alarm.
- Segregate the total Group start board for a lighting division individually.
- Check the Earth Fault pointer for status (still faulty or ordinary).
- Assuming faulty, put on the breaker which is put off before and segregate other gathering start board for lighting circuit.
- When the gathering start board is distinguished, at that point singular lighting switches are killed individually and checked for the alarm condition.
- At the point when any switch when killed and along these lines the condition becomes ordinary, at that point this lighting circuit is stamped and afterward investigation is done on the specific light for anomalies.